Danfoss iC7-Hybrid System Module (IC7SM_HY)
Danfoss iC7-Hybrid System module, liquid-cooled, Grid converter module, GC, 525-690 V AC / 640-1100 V DC, 945 A, Not relevant, IP00/Open Type, 2xAR12L (167F0231)
iC7-60 / System module, liquid-cooled Not relevant 525-690 V AC / 640-1100 V DC IP00/Open Type Frame: 2xAR12L C4 category Control Panel 2.8 OPX20 I/O and Relay Option OC7C1 Voltage Measurement OC7V0 | Temperature Measurement OC7T0 | None, without mounting plate Modbus TCP OS7MT, Ethernet port, no protocol None, not upgradable Latest released version Global
Danfoss iC7-Hybrid System module, liquid-cooled, Inverter module, INU, 525-690 V AC / 640-1100 V DC, 730 A, 710 kW/1000 HP, IP00/Open Type, IR12L (167F0232)
iC7-60 / System module, liquid-cooled 710 kW/1000 HP 525-690 V AC / 640-1100 V DC IP00/Open Type Frame: IR12L C4 category Control Panel 2.8 OPX20 I/O and Relay Option OC7C1 Encoder/Resolver Option OC7M0 | Temperature Measurement OC7T0 | None, without mounting plate Modbus TCP OS7MT, Ethernet port, no protocol None, not upgradable Latest released version […]
Danfoss iC7-Hybrid System module, liquid-cooled, DC/DC converter module, 380-500 V AC / 425-830 V DC, 300 A, Not relevant, IP00/Open Type, DR10L (167H3795)
iC7-60 / System module, liquid-cooled Not relevant 380-500 V AC / 425-830 V DC IP00/Open Type Frame: DR10L C4 category Control Panel 2.8 OPX20 I/O and Relay Option OC7C1 None, without mounting plate Modbus TCP OS7MT, Ethernet port, no protocol None, not upgradable Latest released version Global
Danfoss iC7-Hybrid System module, liquid-cooled, Inverter module, INU, 525-690 V AC / 640-1100 V DC, 2500 A, 2.3 MW, IP00/Open Type, 3xIR12L (167H3563)
iC7-60 / System module, liquid-cooled 2.3 MW 525-690 V AC / 640-1100 V DC IP00/Open Type Frame: 3xIR12L C4 category Control Panel 2.8 OPX20 I/O and Relay Option OC7C1 None, without mounting p | None, without mounting plate Modbus TCP OS7MT, Ethernet port, no protocol None, not upgradable Latest released version Global
Danfoss iC7-Hybrid System module, liquid-cooled, Grid converter module, GC, 525-690 V AC / 640-1100 V DC, 530 A, Not relevant, IP00/Open Type, AR12L (167H3045)
iC7-60 / System module, liquid-cooled Not relevant 525-690 V AC / 640-1100 V DC IP00/Open Type Frame: AR12L C4 category Control Panel 2.8 OPX20 I/O and Relay Option OC7C1 Voltage Measurement OC7V0 | Temperature Measurement OC7T0 | None, without mounting plate Modbus TCP OS7MT, Ethernet port, no protocol None, not upgradable Latest released version Global
Danfoss iC7-Hybrid System module, liquid-cooled, Grid converter module, GC, 525-690 V AC / 640-1100 V DC, 1800 A, Not relevant, IP00/Open Type, 3xAR12L (167H2486)
iC7-60 / System module, liquid-cooled Not relevant 525-690 V AC / 640-1100 V DC IP00/Open Type Frame: 3xAR12L C4 category Control Panel 2.8 OPX20 I/O and Relay Option OC7C1 Voltage Measurement OC7V0 | None, without mounting plate Modbus TCP OS7MT, Ethernet port, no protocol None, not upgradable Latest released version Global
Danfoss iC7-Hybrid System module, liquid-cooled, Grid converter module, GC, 380-690 V AC / 500-1500 V DC, 760 A, Not relevant, IP00/Open Type, AR12L (167H2287)
iC7-60 / System module, liquid-cooled Not relevant 380-690 V AC / 500-1500 V DC IP00/Open Type Frame: AR12L C4 category Control Panel 2.8 OPX20 I/O and Relay Option OC7C1 Voltage Measurement OC7V0 | None, without mounting plate EtherCAT OS7EC, Ethernet port, no protocol None, not upgradable Latest released version Global
Danfoss iC7-Hybrid System module, liquid-cooled, Inverter module, INU, 380-500 V AC / 425-830 V DC., 1760 A, 1.0 MW/1350 HP, IP00/Open Type, 2xIR12L (167H2083)
iC7-60 / System module, liquid-cooled 1.0 MW/1350 HP 380-500 V AC / 425-830 V DC. IP00/Open Type Frame: 2xIR12L C4 category Control Panel 2.8 OPX20 I/O and Relay Option OC7C1 Encoder/Resolver Option OC7M0 | None, without mounting plate Modbus TCP OS7MT, Ethernet port, no protocol None, not upgradable Latest released version Global
Danfoss iC7-Hybrid System module, liquid-cooled, Grid converter module, GC, 380-690 V AC / 500-1500 V DC, 2800 A, Not relevant, IP00/Open Type, 3xAR12L (167H1856)
iC7-60 / System module, liquid-cooled Not relevant 380-690 V AC / 500-1500 V DC IP00/Open Type Frame: 3xAR12L C4 category Control Panel 2.8 OPX20 I/O and Relay Option OC7C1 None, without mounting p | None, without mounting plate EtherCAT OS7EC, Ethernet port, no protocol None, not upgradable Latest released version Global
Danfoss iC7-Hybrid System module, liquid-cooled, Grid converter module, GC, 380-690 V AC / 500-1500 V DC, 2800 A, Not relevant, IP00/Open Type, 3xAR12L (167H1852)
iC7-60 / System module, liquid-cooled Not relevant 380-690 V AC / 500-1500 V DC IP00/Open Type Frame: 3xAR12L C4 category Control Panel 2.8 OPX20 I/O and Relay Option OC7C1 None, without mounting p | None, without mounting plate EtherCAT OS7EC, Ethernet port, no protocol None, not upgradable Latest released version Global
Danfoss iC7-Hybrid System module, liquid-cooled, Grid converter module, GC, 380-690 V AC / 500-1500 V DC, 1900 A, Not relevant, IP00/Open Type, 2xAR12L (167H1855)
iC7-60 / System module, liquid-cooled Not relevant 380-690 V AC / 500-1500 V DC IP00/Open Type Frame: 2xAR12L C4 category Control Panel 2.8 OPX20 I/O and Relay Option OC7C1 Voltage Measurement OC7V0 | I/O and Relay Option OC7C1 | None, without mounting plate PROFINET RT OS7PR, Ethernet port, no protocol None, not upgradable Latest released […]
Danfoss iC7-Hybrid System module, liquid-cooled, Grid converter module, GC, 525-690 V AC / 640-1100 V DC, 760 A, Not relevant, IP00/Open Type, AR12L (167H1825)
iC7-60 / System module, liquid-cooled Not relevant 525-690 V AC / 640-1100 V DC IP00/Open Type Frame: AR12L C4 category Control Panel 2.8 OPX20 I/O and Relay Option OC7C1 Voltage Measurement OC7V0 | I/O and Relay Option OC7C1 | None, without mounting plate Modbus TCP OS7MT, Ethernet port, no protocol None, not upgradable Latest released […]
Danfoss iC7-Hybrid System module, liquid-cooled, Grid converter module, GC, 525-690 V AC / 640-1100 V DC, 760 A, Not relevant, IP00/Open Type, AR12L (167H1558)
iC7-60 / System module, liquid-cooled Not relevant 525-690 V AC / 640-1100 V DC IP00/Open Type Frame: AR12L C4 category Control Panel 2.8 OPX20 I/O and Relay Option OC7C1 Voltage Measurement OC7V0 | I/O and Relay Option OC7C1 | None, without mounting plate Modbus TCP OS7MT, Ethernet port, no protocol None, not upgradable Latest released […]
Danfoss iC7-Hybrid System module, liquid-cooled, Grid converter module, GC, 525-690 V AC / 640-1100 V DC, 2250 A, Not relevant, IP00/Open Type, 3xAR12L (167H1052)
iC7-60 / System module, liquid-cooled Not relevant 525-690 V AC / 640-1100 V DC IP00/Open Type Frame: 3xAR12L C4 category Control Panel 2.8 OPX20 I/O and Relay Option OC7C1 None, without mounting plate PROFINET RT OS7PR, Ethernet port, no protocol None, not upgradable Latest released version Global
Danfoss iC7-Hybrid System module, liquid-cooled, Grid converter module, GC, 380-690 V AC / 500-1500 V DC, 760 A, Not relevant, IP00/Open Type, AR12L (167H0453)
iC7-60 / System module, liquid-cooled Not relevant 380-690 V AC / 500-1500 V DC IP00/Open Type Frame: AR12L C4 category Control Panel 2.8 OPX20 I/O and Relay Option OC7C1 Voltage Measurement OC7V0 | None, without mounting plate PROFINET RT OS7PR, Ethernet port, no protocol None, not upgradable Latest released version Global
Danfoss iC7-Hybrid System module, liquid-cooled, Inverter module, INU, 380-500 V AC / 425-830 V DC, 206 A, 132 kW/200 HP, IP00/Open Type, IR10L (167H0454)
iC7-60 / System module, liquid-cooled 132 kW/200 HP 380-500 V AC / 425-830 V DC IP00/Open Type Frame: IR10L C4 category Control Panel 2.8 OPX20 I/O and Relay Option OC7C1 Encoder/Resolver Option OC7M0 | None, without mounting plate PROFINET RT OS7PR, Ethernet port, no protocol None, not upgradable Latest released version Global
Danfoss iC7-Hybrid System module, liquid-cooled, Grid converter module, GC, 380-690 V AC / 500-1500 V DC, 1900 A, Not relevant, IP00/Open Type, 2xAR12L (167H0325)
iC7-60 / System module, liquid-cooled Not relevant 380-690 V AC / 500-1500 V DC IP00/Open Type Frame: 2xAR12L C4 category Control Panel 2.8 OPX20 I/O and Relay Option OC7C1 Voltage Measurement OC7V0 | None, without mounting plate PROFINET RT OS7PR, Ethernet port, no protocol None, not upgradable Latest released version Global
Danfoss iC7-Hybrid System module, liquid-cooled, DC/DC converter module, 380-500 V AC / 425-830 V DC, 300 A, Not relevant, IP00/Open Type, DR10L (167G9346)
iC7-60 / System module, liquid-cooled Not relevant 380-500 V AC / 425-830 V DC IP00/Open Type Frame: DR10L C4 category Control Panel 2.8 OPX20 I/O and Relay Option OC7C1 I/O and Relay Option OC7C1 | Temperature Measurement OC7T0 | None, without mounting plate Modbus TCP OS7MT, Ethernet port, no protocol None, not upgradable Latest released […]
Danfoss iC7-Hybrid System module, liquid-cooled, DC/DC converter module, 380-500 V AC / 425-830 V DC, 720 A, Not relevant, IP00/Open Type, DR12L (167G8456)
iC7-60 / System module, liquid-cooled Not relevant 380-500 V AC / 425-830 V DC IP00/Open Type Frame: DR12L C4 category Control Panel 2.8 OPX20 I/O and Relay Option OC7C1 I/O and Relay Option OC7C1 | Temperature Measurement OC7T0 | None, without mounting plate Modbus TCP OS7MT, Ethernet port, no protocol None, not upgradable Latest released […]
Danfoss iC7-Hybrid System module, liquid-cooled, Grid converter module, GC, 525-690 V AC / 640-1100 V DC, 760 A, Not relevant, IP00/Open Type, AR12L (167G8958)
iC7-60 / System module, liquid-cooled Not relevant 525-690 V AC / 640-1100 V DC IP00/Open Type Frame: AR12L C4 category Control Panel 2.8 OPX20 I/O and Relay Option OC7C1 Voltage Measurement OC7V0 | None, without mounting plate PROFINET RT OS7PR, Ethernet port, no protocol None, not upgradable Latest released version Global
Danfoss iC7-Hybrid System module, liquid-cooled, Grid converter module, GC, 380-690 V AC / 500-1500 V DC, 5550 A, Not relevant, IP00/Open Type, 6xAR12L (167G0798)
iC7-60 / System module, liquid-cooled Not relevant 380-690 V AC / 500-1500 V DC IP00/Open Type Frame: 6xAR12L C4 category Control Panel 2.8 OPX20 I/O and Relay Option OC7C1 None, without mounting p | None, without mounting plate Modbus TCP OS7MT, Ethernet port, no protocol None, not upgradable Latest released version Global
Danfoss iC7-Hybrid System module, liquid-cooled, Grid converter module, GC, 525-690 V AC / 640-1100 V DC, 760 A, Not relevant, IP00/Open Type, AR12L (137X9426)
iC7-60 / System module, liquid-cooled Not relevant 525-690 V AC / 640-1100 V DC IP00/Open Type Frame: AR12L C4 category Control Panel 2.8 OPX20 I/O and Relay Option OC7C1 Voltage Measurement OC7V0 | None, without mounting plate Modbus TCP OS7MT, Ethernet port, no protocol None, not upgradable Latest released version Global
Danfoss iC7-Hybrid System module, liquid-cooled, Grid converter module, GC, 525-690 V AC / 640-1100 V DC, 595 A, Not relevant, IP00/Open Type, AR12L (137X8612)
iC7-60 / System module, liquid-cooled Not relevant 525-690 V AC / 640-1100 V DC IP00/Open Type Frame: AR12L C4 category Control Panel 2.8 OPX20 I/O and Relay Option OC7C1 Voltage Measurement OC7V0 | None, without mounting plate Modbus TCP OS7MT, Ethernet port, no protocol None, not upgradable Latest released version Global