Danfoss iC7-Hybrid System module, liquid-cooled, Grid converter module, GC, 525-690 V AC / 640-1100 V DC, 2250 A, Not relevant, IP00/Open Type, 3xAR12L (167H1052)
iC7-60 / System module, liquid-cooled Not relevant 525-690 V AC / 640-1100 V DC IP00/Open Type Frame: 3xAR12L C4 category Control Panel 2.8 OPX20 I/O and Relay Option OC7C1 None, without mounting plate PROFINET RT OS7PR, Ethernet port, no protocol None, not upgradable Latest released version Global
Danfoss iC7-Hybrid System module, liquid-cooled, Grid converter module, GC, 380-690 V AC / 500-1500 V DC, 760 A, Not relevant, IP00/Open Type, AR12L (167H0453)
iC7-60 / System module, liquid-cooled Not relevant 380-690 V AC / 500-1500 V DC IP00/Open Type Frame: AR12L C4 category Control Panel 2.8 OPX20 I/O and Relay Option OC7C1 Voltage Measurement OC7V0 | None, without mounting plate PROFINET RT OS7PR, Ethernet port, no protocol None, not upgradable Latest released version Global
Danfoss iC7-Hybrid System module, liquid-cooled, Inverter module, INU, 380-500 V AC / 425-830 V DC, 206 A, 132 kW/200 HP, IP00/Open Type, IR10L (167H0454)
iC7-60 / System module, liquid-cooled 132 kW/200 HP 380-500 V AC / 425-830 V DC IP00/Open Type Frame: IR10L C4 category Control Panel 2.8 OPX20 I/O and Relay Option OC7C1 Encoder/Resolver Option OC7M0 | None, without mounting plate PROFINET RT OS7PR, Ethernet port, no protocol None, not upgradable Latest released version Global
Danfoss iC7-Hybrid System module, liquid-cooled, Grid converter module, GC, 380-690 V AC / 500-1500 V DC, 1900 A, Not relevant, IP00/Open Type, 2xAR12L (167H0325)
iC7-60 / System module, liquid-cooled Not relevant 380-690 V AC / 500-1500 V DC IP00/Open Type Frame: 2xAR12L C4 category Control Panel 2.8 OPX20 I/O and Relay Option OC7C1 Voltage Measurement OC7V0 | None, without mounting plate PROFINET RT OS7PR, Ethernet port, no protocol None, not upgradable Latest released version Global
Danfoss iC7-Marine System module, liquid-cooled, 3~, regenerative, AFE, 525-690 V AC / 640-1100 V DC, 1325 A, Not relevant, IP00/Open Type, 2xAR12L (167H0073)
iC7-60 / System module, liquid-cooled Not relevant 525-690 V AC / 640-1100 V DC IP00/Open Type Frame: 2xAR12L C4 category Control Panel 2.8 OPX20 I/O and Relay Option OC7C1 None, without mounting p | None, without mounting plate Modbus TCP OS7MT, Ethernet port, no protocol None, not upgradable Latest released version Global
Danfoss iC7-Marine System module, liquid-cooled, Inverter module, INU, 525-690 V AC / 640-1100 V DC, 3260 A, 3.0 MW, IP00/Open Type, 4xIR12L (167H0068)
iC7-60 / System module, liquid-cooled 3.0 MW 525-690 V AC / 640-1100 V DC IP00/Open Type Frame: 4xIR12L C4 category Control Panel 2.8 OPX20 I/O and Relay Option OC7C1 General Purpose I/O OC7C0 | Encoder/Resolver Option OC7M0 | Temperature Measurement OC7T0 | None, without mounting plate Modbus TCP OS7MT, Ethernet port, no protocol None, not […]
Danfoss iC7-Marine System module, liquid-cooled, Inverter module, INU, 380-500 V AC / 425-830 V DC., 245 A, 132 kW/200 HP, IP00/Open Type, IM10L (167G9345)
iC7-60 / System module, liquid-cooled 132 kW/200 HP 380-500 V AC / 425-830 V DC. IP00/Open Type Frame: IM10L C4 category Control Panel 2.8 OPX20 I/O and Relay Option OC7C1 I/O and Relay Option OC7C1 | Temperature Measurement OC7T0 | None, without mounting plate Modbus TCP OS7MT, Ethernet port, no protocol None, not upgradable Latest […]
Danfoss iC7-Automation System module, air-cooled, 3~, regenerative, AFE, 380-500 V AC, 317 A, Not relevant, IP00/Open Type, AR10 (167G9404)
iC7-60 / System module, air-cooled Not relevant 380-500 V AC IP00/Open Type Frame: AR10 C3 category Control Panel 2.8 OPX20 I/O and Relay Option OC7C1 None, without mounting plate Modbus TCP OS7MT, Ethernet port, no protocol None, not upgradable Latest released version Global
Danfoss iC7-Hybrid System module, liquid-cooled, DC/DC converter module, 380-500 V AC / 425-830 V DC, 300 A, Not relevant, IP00/Open Type, DR10L (167G9346)
iC7-60 / System module, liquid-cooled Not relevant 380-500 V AC / 425-830 V DC IP00/Open Type Frame: DR10L C4 category Control Panel 2.8 OPX20 I/O and Relay Option OC7C1 I/O and Relay Option OC7C1 | Temperature Measurement OC7T0 | None, without mounting plate Modbus TCP OS7MT, Ethernet port, no protocol None, not upgradable Latest released […]
Danfoss iC7-Automation System module, air-cooled, 3~, low-harmonic, AFE, 380-500 V AC, 400 A, Not relevant, IP00/Open Type, AR10 (167G9270)
iC7-60 / System module, air-cooled Not relevant 380-500 V AC IP00/Open Type Frame: AR10 C3 category Control Panel 2.8 OPX20 I/O and Relay Option OC7C1 None, without mounting p | None, without mounting plate Modbus TCP OS7MT, Ethernet port, no protocol None, not upgradable Latest released version Global
Danfoss iC7-Marine System module, liquid-cooled, 3~, regenerative, AFE, 525-690 V AC / 640-1100 V DC, 1500 A, Not relevant, IP00/Open Type, 2xAR12L (167G8498)
iC7-60 / System module, liquid-cooled Not relevant 525-690 V AC / 640-1100 V DC IP00/Open Type Frame: 2xAR12L C4 category Control Panel 2.8 OPX20 I/O and Relay Option OC7C1 None, without mounting p | None, without mounting plate Modbus TCP OS7MT, Ethernet port, no protocol None, not upgradable Latest released version Global
Danfoss iC7-Automation System module, air-cooled, 3~, low-harmonic, AFE, 380-500 V AC, 1210 A, Not relevant, IP00/Open Type, 2xAM11 (167G9267)
iC7-60 / System module, air-cooled Not relevant 380-500 V AC IP00/Open Type Frame: 2xAM11 C3 category Control Panel 2.8 OPX20 I/O and Relay Option OC7C1 None, without mounting p | None, without mounting plate PROFINET RT OS7PR, Ethernet port, no protocol None, not upgradable Latest released version Global
Danfoss iC7-Marine System module, liquid-cooled, Brake chopper module, BCU, 380-500 V AC / 425-830 V DC, 261 A, Not relevant, IP00/Open Type, BR10L (167G9158)
iC7-60 / System module, liquid-cooled Not relevant 380-500 V AC / 425-830 V DC IP00/Open Type Frame: BR10L C4 category Control Panel 2.8 OPX20 I/O and Relay Option OC7C1 None, without mounting plate Modbus TCP OS7MT, Ethernet port, no protocol None, not upgradable Latest released version Global
Danfoss iC7-Marine System module, liquid-cooled, Inverter module, INU, 380-500 V AC / 425-830 V DC, 820 A, 560 kW/750 HP, IP00/Open Type, IR12L (167G8457)
iC7-60 / System module, liquid-cooled 560 kW/750 HP 380-500 V AC / 425-830 V DC IP00/Open Type Frame: IR12L C4 category Control Panel 2.8 OPX20 I/O and Relay Option OC7C1 Encoder/Resolver Option OC7M0 | I/O and Relay Option OC7C1 | Temperature Measurement OC7T0 Modbus TCP OS7MT, Ethernet port, no protocol None, not upgradable Latest released […]
Danfoss iC7-Hybrid System module, liquid-cooled, DC/DC converter module, 380-500 V AC / 425-830 V DC, 720 A, Not relevant, IP00/Open Type, DR12L (167G8456)
iC7-60 / System module, liquid-cooled Not relevant 380-500 V AC / 425-830 V DC IP00/Open Type Frame: DR12L C4 category Control Panel 2.8 OPX20 I/O and Relay Option OC7C1 I/O and Relay Option OC7C1 | Temperature Measurement OC7T0 | None, without mounting plate Modbus TCP OS7MT, Ethernet port, no protocol None, not upgradable Latest released […]
Danfoss iC7-Hybrid System module, liquid-cooled, Grid converter module, GC, 525-690 V AC / 640-1100 V DC, 760 A, Not relevant, IP00/Open Type, AR12L (167G8958)
iC7-60 / System module, liquid-cooled Not relevant 525-690 V AC / 640-1100 V DC IP00/Open Type Frame: AR12L C4 category Control Panel 2.8 OPX20 I/O and Relay Option OC7C1 Voltage Measurement OC7V0 | None, without mounting plate PROFINET RT OS7PR, Ethernet port, no protocol None, not upgradable Latest released version Global
Danfoss iC7-Hybrid System module, liquid-cooled, Grid converter module, GC, 380-690 V AC / 500-1500 V DC, 5550 A, Not relevant, IP00/Open Type, 6xAR12L (167G0798)
iC7-60 / System module, liquid-cooled Not relevant 380-690 V AC / 500-1500 V DC IP00/Open Type Frame: 6xAR12L C4 category Control Panel 2.8 OPX20 I/O and Relay Option OC7C1 None, without mounting p | None, without mounting plate Modbus TCP OS7MT, Ethernet port, no protocol None, not upgradable Latest released version Global
Danfoss iC7-Marine System module, liquid-cooled, 3~, regenerative, AFE, 525-690 V AC / 640-1100 V DC, 2250 A, Not relevant, IP00/Open Type, 3xAR12L (167G8118)
iC7-60 / System module, liquid-cooled Not relevant 525-690 V AC / 640-1100 V DC IP00/Open Type Frame: 3xAR12L C4 category Control Panel 2.8 OPX20 I/O and Relay Option OC7C1 None, without mounting p | None, without mounting plate Modbus TCP OS7MT, Ethernet port, no protocol None, not upgradable Latest released version Global
Danfoss iC7-Automation System module, air-cooled, 3~, regenerative, AFE, 380-500 V AC, 514 A, Not relevant, IP00/Open Type, AR10 (137X9597)
iC7-60 / System module, air-cooled Not relevant 380-500 V AC IP00/Open Type Frame: AR10 C3 category Control Panel 2.8 OPX20 I/O and Relay Option OC7C1 I/O and Relay Option OC7C1 | None, without mounting plate PROFINET RT OS7PR, Ethernet port, no protocol None, not upgradable Latest released version Global
Danfoss iC7-Hybrid System module, liquid-cooled, Grid converter module, GC, 525-690 V AC / 640-1100 V DC, 760 A, Not relevant, IP00/Open Type, AR12L (137X9426)
iC7-60 / System module, liquid-cooled Not relevant 525-690 V AC / 640-1100 V DC IP00/Open Type Frame: AR12L C4 category Control Panel 2.8 OPX20 I/O and Relay Option OC7C1 Voltage Measurement OC7V0 | None, without mounting plate Modbus TCP OS7MT, Ethernet port, no protocol None, not upgradable Latest released version Global
Danfoss iC7-Automation System module, air-cooled, 3~, low-harmonic, AFE, 380-500 V AC, 1630 A, Not relevant, IP00/Open Type, 2xAR11 (137X9074)
iC7-60 / System module, air-cooled Not relevant 380-500 V AC IP00/Open Type Frame: 2xAR11 C3 category Control Panel 2.8 OPX20 I/O and Relay Option OC7C1 None, without mounting p | None, without mounting plate Modbus TCP OS7MT, Ethernet port, no protocol None, not upgradable Latest released version Global
Danfoss iC7-Hybrid System module, liquid-cooled, Grid converter module, GC, 525-690 V AC / 640-1100 V DC, 595 A, Not relevant, IP00/Open Type, AR12L (137X8612)
iC7-60 / System module, liquid-cooled Not relevant 525-690 V AC / 640-1100 V DC IP00/Open Type Frame: AR12L C4 category Control Panel 2.8 OPX20 I/O and Relay Option OC7C1 Voltage Measurement OC7V0 | None, without mounting plate Modbus TCP OS7MT, Ethernet port, no protocol None, not upgradable Latest released version Global
Danfoss iC7-Hybrid System module, liquid-cooled, Grid converter module, GC, 525-690 V AC / 640-1100 V DC, 595 A, Not relevant, IP00/Open Type, AR12L (137X8613)
iC7-60 / System module, liquid-cooled Not relevant 525-690 V AC / 640-1100 V DC IP00/Open Type Frame: AR12L C4 category Control Panel 2.8 OPX20 I/O and Relay Option OC7C1 Voltage Measurement OC7V0 | None, without mounting plate Modbus TCP OS7MT, Ethernet port, no protocol None, not upgradable Latest released version Global
Danfoss iC7-Hybrid System module, liquid-cooled, Grid converter module, GC, 380-500 V AC / 425-830 V DC, 380 A, Not relevant, IP00/Open Type, AM10L (137X8136)
iC7-60 / System module, liquid-cooled Not relevant 380-500 V AC / 425-830 V DC IP00/Open Type Frame: AM10L C3 category Control Panel 2.8 OPX20 Voltage Measurement OC7V0 | I/O and Relay Option OC7C1 Ethernet port, no protocol None, not upgradable Latest released version Global