| Teknik Parametre | Değer |
|---|---|
| OPTIONS C2 | X||X No Option C2 |
| Output frequency | 3ph, 0-60 Hz||3ph, 0-60 Hz |
| Minimum Temperature Rating | 0degC/32degF||0degC/32degF |
| Calculated Gross Weight [kg] | 57.820 |
| SWITCHES | M||M Main Disconnect Switch |
| Label - Frame | Frame B1||Frame B1 |
| OPTIONS A | X||X No Communication Cards |
| Input frequency | 3ph, 60 Hz,||3ph, 60 Hz, |
| Label stock used for printing | 176U9528||176U9528 |
| Vendor | ERR01||Cannot Determine Vendor |
| Fuse 1 ID | F15A, B, C||F15A, B, C |
| OPTIONS C1 | X||X No Option C0 |
| Layout Drawing Number | 176U8472||176U8472 |
| Panel Tier Indicator | Tier 2||Tier 2 |
| Label Template | OP100_E01_12_Danfoss_PL.btw||OP100_E01_12_Danfoss_PL.btw |
| CONTROL SELECTION A | 1||Electronic controlled bypass |
| ELECTRICAL LAYOUT | 176U5307||176U5307 |
| Typecode Part 2 | XXZ2XGXXXXXXXXXXXXXE |
| VOLTAGE | T1||T1 208 Volt |
| Enclosure rating | UL Type 1||UL Type 1 |
| Modelcode01 | S103010T1E013CMN1XXS |
| Company Service Info #4 | Fax.: +1 (815) 639-8002||Fax.: +1 (815) 639-8002 |
| Modelcode02 | XXZ2XGXXXXXXXXXXXXXE |
| Connection 1 Type | Use 75 C Copper Cond.||Use 75 C Copper Cond. |
| Company Service Info #3 | Tel.: +1 (800) 432-6367||Tel.: +1 (800) 432-6367 |
| SOFTWARE RELEASE | XXX||Latest Software Release |
| Ambient temp. normal overload | 45degC/113degF||45degC/113degF |
| OPTIONS B | X||X No Input/Output Cards |
| Humidity | 95% Non-Cond.||95% Non-Cond. |
| BRAKE | X||X No Brake Chopper |
| Plant from Orderline | F608||F608 |
| Fuse 1 Manufacturer | -||- |
| Calculated Net Weight [kg] | 39.680 |
| Connection 6 Torque | 7 (0.8)||7 (0.8) |
| Reactor | X||No Reactor/Filter |
| Connection 6 ID | TB1, TB2||TB1, TB2 |
| Frames Size for OP_103 | B1||B1 |
| ENCLOSURE LAYOUT | 176U3837||176U3837 |
| Panel Schematic | 007N0948||007N0948 |
| Tier | 2||Tier 2 |
| Typecode Part 1 | S103010T1E013CMN1XXS |
| Installation Drawing | 176U8472||176U8472 |
| Connection 6 Type | Use Copper Cond.||Use Copper Cond. |
| ADAPTATION A | X||No Adapation A |
| Company Service Info #1 | See manual 176R0585||See manual 176R0585 |
| Panel OSHPD 4 | SDS: 1.58, z/h: 1.0, ip: 1.5||SDS: 1.58, z/h: 1.0, ip: 1.5 |
| Drive Typecode Part 1 | FC-103P7K5T2E21H2XXX||FC-103P7K5T2E21H2XXX |
| Calculated Gross Weight (lbs) | 127.471 |
| RFI | 2||2 RFI Filter Standard |
| Drive Typecode Part 2 | 7XXSXXXXAXBXCXXXXDX||7XXSXXXXAXBXCXXXXDX |
| Calculated Net Weight [lbs] | 87.479 |
| ECCN US | 3A999.a||3A999.a |
| SERIES | 103||103 Refrigeration Drive |
| Connection 2 Type | Use 75 C Copper Cond.||Use 75 C Copper Cond. |
| SOFTWARE LANGUAGE | X||Standard Language Pack |
| Product View (Switch) | NAMC||North America (Regional) |
| Short circuit current rating | 100 kA||100 kA |
| MOTOR #1 | X||X |
| Panel OSHPD 2 | OSP-0087||OSP-0087 |
| Panel OSHPD 3 | Anchorage: Rigid Wall Mount||Anchorage: Rigid Wall Mount |
| Connection 2 ID | T1, T2, T3/ GND||T1, T2, T3/ GND |
| Fuse 5 Type | FWH-020A6F 20A||FWH-020A6F 20A |
| Input Voltage | 208 VAC,||208 VAC, |
| PREFIX | S||S Standard |
| Fuse 5 ID | F900,F901,F902||F900,F901,F902 |
| Connection 2 Torque | 35 (4.0)/ 25 (2.8)||35 (4.0)/ 25 (2.8) |
| Schematic | 007N0948||007N0948 |
| MOTOR #2 | X||X |
| Cross-Plant Configurable Material | STD. Panel Configurator FC-103 |
| Motor HP Rating (Single/CMS) | 10 HP,||10 HP, |
| Company info 3 | Tel.: +1 (800) 432-6367||Tel.: +1 (800) 432-6367 |
| Motor FLA Rating (Single/CMS) | 30.8 A,||30.8 A, |
| COATING | X||X No Conformal Coating |
| Company info 4 | Fax.: +1 (815) 639-8002||Fax.: +1 (815) 639-8002 |
| Company info 1 | Danfoss LLC||Danfoss LLC |
| Company info 2 | Milwaukee, WI 53224, U.S.A.||Milwaukee, WI 53224, U.S.A. |
| POWER RATING STYLE | X||X Current Style A-C frame |
| HORSEPOWER | 010||010 10 HP |
| OPTIONS D | E||E ECB 24V dc backup |
| Connection 1 ID | L1, L2, L3/ GND||L1, L2, L3/ GND |
| Connection 1 Torque | 30 (3.4)/ 25 (2.8)||30 (3.4)/ 25 (2.8) |
| Fuse 5 Manufacturer | Bussmann||Bussmann |
| Panel OSHPD 1 | OSHPD Pre-Approval:||OSHPD Pre-Approval: |
| MOTOR QUANTITY | S||S Single Motor |
| ADAPTATION B | X||No Adapation B |
| ENCLOSURE | E01||E01 Nema 1 |
| ECCN EU | Y901||Y901 |
| Fuse 2 Type | JJN-50||JJN-50 |
| FUSING | N||N 100kA SCCR |
| FUTURE OPTION | Z||NONE |
| Fuse 2 Manufacturer | Bussmann||Bussmann |
| Fuse 1 Type | 600 VAC, 50 A, CLASS J||600 VAC, 50 A, CLASS J |
| DISPLAY | G||G Graphical |
| Input current in Normal Overlo | 31.4 A,||31.4 A, |
| OPTIONS C3 | XX||XX No Software option |
| Product Catalog | NO_VIEW||NO VIEW |
| Fuse 2 ID | F16A, B, C||F16A, B, C |
| BYPASS | 3C||3C 3 Contactor Bypass |
Evet, DES Teknoloji, Danfoss Türkiye partneridir. İncelediğiniz Danfoss S Standard 103 Refrigeration Drive, 010 10 HP, T1 208 Volt, E01 Nema 1, 3C 3 Contactor Bypass, B1 ürünü %100 orijinal olup fabrika garantisi altındadır.
Evet. DES Teknoloji olarak uzman mühendis kadromuzla Danfoss sürücüleriniz için yetkili bakım, onarım, yedek parça ve test hizmeti sunmaktayız.
Satış sonrası mühendislik hizmetlerimiz kapsamında cihazın pano montajı, parametre ayarları ve sahada devreye alınması konularında teknik destek sağlamaktayız.
Sayfadaki 'Proje İçin Teklif Alın' butonuna tıklayarak veya iletişim numaralarımızdan satış mühendislerimize ulaşarak özel iskontolu fiyat teklifinizi hemen alabilirsiniz.