| Teknik Parametre | Değer |
|---|---|
| Output frequency | 25-70Hz||25-70Hz |
| Product Category -DrivesSymbol | System module, liquid-cooled||System module, liquid-cooled |
| Calculated Gross Weight [kg] | 272.000 |
| Liquid temp. High Overload | 45°C/113°F||45°C/113°F |
| Product Type - DrivesSymbol | Grid converter module||Grid converter module |
| Liquid temp. Low Overload | 45°C/113°F||45°C/113°F |
| Power rating | XXX||Not relevant |
| Cooling circuit hose length | +AO20||2.0 m (6 ft)##Coolant hoses for water with a length of 2.0m (6 ft) for each inlet and outlet connector. Note, only available for the Push-in connector. |
| Salescode part 8 | +VBBV||+VBBV |
| Input frequency | 50/60Hz||50/60Hz |
| Liquid temp. Nominal load | 45°C/113°F||45°C/113°F |
| Communication interface, X0 | +BBEL||Ethernet port, no protocol##Control card with Ethernet port X0, but no embedded protocol - can be upgraded later |
| Vendor | ERR01||Cannot Determine Vendor |
| Modelcode05 | +CCT0 |
| Control panel mounting type | +BGK1||Flush mount##Flush mounting kit for control panel |
| Modelcode08 | +EGIN+EHEN |
| Modelcode06 | +DAHY |
| Product Catalog | NO_VIEW||NO VIEW |
| Typecode Part 2 | -000213471 |
| Enclosure rating | IP00 / OPEN TYPE||IP00 / OPEN TYPE |
| Shipping package | +TACB||Cardboard box package |
| Modelcode01 | IC7-60SLGC07-530AE00F4 |
| Protection rating | E00||IP00/Open Type |
| Modelcode02 | +AEZ1+AJFX+AKFX+ANN1 |
| Salescode part 1 | IC7-60SLGC07-530AE00F4||IC7-60SLGC07-530AE00F4 |
| Standard I/O | +BDC1||I/O and Relay Option OC7C1##Basic I/O option (6 DI, 2 DO, 2 AI, 1 AO, thermistor input, 2 NO/NC & 1NO relays) |
| StarCoupler board cable length | +BL50||5.0 m (16 ft), Fiber##Optical fiber cable 5.0 m (16 ft) |
| Main unit Height | 1295mm/51in||1295mm/51in |
| Salescode part 4 | +BGK1+BH25+BK03+BL50+CAV0+CBT0||+BGK1+BH25+BK03+BL50+CAV0+CBT0 |
| Product type | GC||Grid converter module, GC |
| Plant from Orderline | D801||D801 |
| Brand | iC7 |
| Technical documentation | +EGIN||Installation guide##Includes Installation Guide and Safety Guide |
| Cooling circuit connector type | +ANN1||Push-in connection##Coolant connector included with push-in type of connection - See Technical Documentation for detailed information |
| Product specific marine cert. | +VBBV||Bureau Veritas##Bureau Veritas |
| Salescode part 3 | +AO20+BAMT+BDC1+BEXX+BF20||+AO20+BAMT+BDC1+BEXX+BF20 |
| Calculated Net Weight [kg] | 230.000 |
| Option slot F | +CFXX||None, without mounting plate##No option - Field upgrade not possible |
| Product software ID | +ECXXX||Latest released version##Latest official released version |
| DC Bus current | 619A(1025VDC)||619A(1025VDC) |
| Product View (Switch) | GLBL||Global (Standard) |
| Additional drive features 4 | +DG4X||None |
| Cooling type | Liquid Cooled||Liquid Cooled |
| DC power | 634kW(1025VDC)||634kW(1025VDC) |
| Frame designation | AR12L||AR12L |
| Recommended Plant | ERR01||ERR01 |
| Salescode part 2 | +AEZ1+AJFX+AKFX+ANN1||+AEZ1+AJFX+AKFX+ANN1 |
| Option slot H | +CHXX||None, without mounting plate##No option - Field upgrade not possible |
| Option slot I | +CIXX||None, without mounting plate##No option - Field upgrade not possible |
| Typecode Part 1 | 7SM-HYSLGC07-530AE00F4 |
| Option slot J | +CJXX||None, without mounting plate##No option - Field upgrade not possible |
| Main unit Depth | 566mm/22.3in||566mm/22.3in |
| Modelcode09 | +VBBV |
| Option slot D | +CDXX||None, without mounting plate##No option - Field upgrade not possible |
| Modelcode04 | +BGK1+BH25+BK03+BL50+CAV0+CBT0 |
| Product category | SL||System module, liquid-cooled |
| Current rating | -530A||530 A |
| Salescode part 7 | +EGIN+EHEN||+EGIN+EHEN |
| ECCN US | 3A999.a||3A999.a |
| Additional drive features 1 | +DD1X||None |
| Option slot G | +CGXX||None, without mounting plate##No option - Field upgrade not possible |
| Additional drive features 5 | +DH5X||None |
| Control panel | +BF20||Control Panel 2.8 OPX20##Control Panel with user interface, status and fieldbus indicators |
| Additional drive features 3 | +DF3X||None |
| Product group | IC7-60||iC7-60##Product is based on iC7-60 hardware series |
| Product series | +DAHY||iC7-Hybrid |
| Additional drive features 2 | +DE2X||None |
| Nominal AC current | 542A||542A |
| Short circuit current rating | 100kA||100kA |
| Mains voltage | 07||525-690 V AC / 640-1100 V DC##Voltage range 525-690 V AC / 640-1100V DC |
| Documentation language | +EHEN||English |
| Option slot A | +CAV0||Voltage Measurement OC7V0##2 inputs, AC voltage (0-759VAC) or DC voltage (0-1354VDC) |
| Option slot B | +CBT0||Temperature Measurement OC7T0##Option with 5 inputs for 2-wire, 3-wire or 4-wire temperature sensors (Pt100, Pt1000, Ni1000, KTY types) |
| Modelcode03 | +AO20+BAMT+BDC1+BEXX+BF20 |
| Option slot E | +CEXX||None, without mounting plate##No option - Field upgrade not possible |
| Option slot C | +CCT0||Temperature Measurement OC7T0##Option with 5 inputs for 2-wire, 3-wire or 4-wire temperature sensors (Pt100, Pt1000, Ni1000, KTY types) |
| Cross-Plant Configurable Material | iC7-Hybrid System Module |
| DC fuses and devices | +AKFX||DC bus fuses##Input protection with DC fuses |
| Marine construction | +AFXX||None##Liquid cooled system modules allow two power cables per phase asstandard. Power terminal adapter allows three parallel but smallercross-section power cables. |
| check if complete | OK||OK |
| Mains input device | +AJFX||AC fuses##Input protection with AC fuses |
| Storage temperature | -40...70°C/-40...158°F||-40...70°C/-40...158°F |
| Integration unit | +AEZ1||Standard, with LC filter##Standard Integration unit with LC filter |
| Language package | +EL01||Global##Global language package - See Technical Documentation for detailed information |
| Main unit Width | 235mm/9.3in||235mm/9.3in |
| Functional safety | +BEXX||None, not upgradable##No functional safety supported - not possible to upgrade later with FS related functionality |
| Communication interface, X1/X2 | +BAMT||Modbus TCP OS7MT##Modbus TCP - PRP. Safe fieldbus not possible. |
| Customer-specific label | +EJXX||None##No customer specific information printed on product label |
| Customization file package ID | +EAXXXXXX||No customization##No customer specific settings |
| ECCN EU | Y901||Y901 |
| Apparent power | /564kVA(600VAC)||/564kVA(600VAC) |
| High speed enabled | +DI6X||No##Output frequency limited to 590 Hz |
| Apparent power | 648kVA(690VAC)||648kVA(690VAC) |
| EMC category | F4||C4 category##Suitable in systems with rated currents <gt/>= 400 A or IT supply systems for use in complex systems in the second environment. EMC plan required. |
| Extra environmental protection | +AGCX||Coated boards##Coated printed circuit board for extra protection |
| Salescode part 6 | +DAHY||+DAHY |
| Marine Certificate Number | 141F8723||141F8723 |
| Control panel cable length | +BH25||2.5 m (8 ft)##Extension cable 2.5m (8ft) |
| Salescode part 5 | +CCT0||+CCT0 |
| AC voltage | 3X525-690VAC||3X525-690VAC |
| Power factor | cos φ = 0 ind. to 0 cap.||cos φ = 0 ind. to 0 cap. |
| DC Bus voltage | 640-1100VDC||640-1100VDC |
| Control unit cable length | +BK03||0.3 m (1 ft), Fiber##Optical fiber cable 0.3 m (1 ft) |
| Customer specific application | +DBXX||None |
Evet, DES Teknoloji, Danfoss Türkiye partneridir. İncelediğiniz Danfoss iC7-Hybrid System module, liquid-cooled, Grid converter module, GC, 525-690 V AC / 640-1100 V DC, 530 A, Not relevant, IP00/Open Type, AR12L ürünü %100 orijinal olup fabrika garantisi altındadır.
Evet. DES Teknoloji olarak uzman mühendis kadromuzla Danfoss sürücüleriniz için yetkili bakım, onarım, yedek parça ve test hizmeti sunmaktayız.
Satış sonrası mühendislik hizmetlerimiz kapsamında cihazın pano montajı, parametre ayarları ve sahada devreye alınması konularında teknik destek sağlamaktayız.
Sayfadaki 'Proje İçin Teklif Alın' butonuna tıklayarak veya iletişim numaralarımızdan satış mühendislerimize ulaşarak özel iskontolu fiyat teklifinizi hemen alabilirsiniz.