Bizi Arayın

+90 216 420 30 56

Danfoss iC7-Marine System module, liquid-cooled, 3~, regenerative, AFE, 525-690 V AC / 640-1100 V DC, 1230 A, Not relevant, IP00/Open Type, 2xAR12L

Sipariş / Malzeme Kodu: 167G6096 Kopyalandı ✓
Model Kodu (Typecode): 7SM-MASL3A07-1230E00F4+AEZ1+AJFX+AKFX+ANN1+AO20+BAMT+BDC1+BEXX+BF20+BGK1+BH15+BK03+BL25+DAMA+EGIN+EHEN+VBAB Kopyalandı ✓
Öne Çıkan Özellikler
  • • iC7-60 / System module, liquid-cooled
  • • Not relevant
  • • 525-690 V AC / 640-1100 V DC
  • • IP00/Open Type
  • • Frame: 2xAR12L
  • • C4 category
  • • Control Panel 2.8 OPX20
  • • I/O and Relay Option OC7C1
  • • None, without mounting p | None, without mounting plate
  • • Modbus TCP OS7MT, Ethernet port, no protocol
  • • None, not upgradable
  • • Latest released version
  • • Global
Teknik Parametre Değer
Product Category -DrivesSymbol System module, liquid-cooled||System module, liquid-cooled
Calculated Gross Weight [kg] 544.000
Liquid temp. High Overload 45°C/113°F||45°C/113°F
Product Type - DrivesSymbol 3 phase regenerative, AFE||3 phase regenerative, AFE
Liquid temp. Low Overload 45°C/113°F||45°C/113°F
Power rating XXX||Not relevant
Cooling circuit hose length +AO20||2.0 m (6 ft)##Coolant hoses for water with a length of 2.0m (6 ft) for each inlet and outlet connector. Note, only available for the Push-in connector.
Input frequency 50/60Hz||50/60Hz
Liquid temp. Nominal load 45°C/113°F||45°C/113°F
Communication interface, X0 +BBEL||Ethernet port, no protocol##Control card with Ethernet port X0, but no embedded protocol - can be upgraded later
Salescode part 2 +AEZ1+AJFX+AKFX+ANN1||+AEZ1+AJFX+AKFX+ANN1
Vendor ERR01||Cannot Determine Vendor
Control panel mounting type +BGK1||Flush mount##Flush mounting kit for control panel
Modelcode08 +EGIN+EHEN
Modelcode06 +DAMA
Product Catalog NO_VIEW||NO VIEW
Typecode Part 2 -000197596
Enclosure rating IP00 / OPEN TYPE||IP00 / OPEN TYPE
Shipping package +TACB||Cardboard box package
Modelcode01 IC7-60SL3A07-1230E00F4
Protection rating E00||IP00/Open Type
Modelcode02 +AEZ1+AJFX+AKFX+ANN1
Standard I/O +BDC1||I/O and Relay Option OC7C1##Basic I/O option (6 DI, 2 DO, 2 AI, 1 AO, thermistor input, 2 NO/NC & 1NO relays)
Salescode part 5 +DAMA||+DAMA
StarCoupler board cable length +BL25||2.5 m (8 ft), Fiber##Optical fiber cable 2.5 m (8 ft)
Main unit Height 1295mm/51in||1295mm/51in
Product type 3A||3~, regenerative, AFE##Active Front End - three phase supply
Brand iC7
Technical documentation +EGIN||Installation guide##Includes Installation Guide and Safety Guide
Cooling circuit connector type +ANN1||Push-in connection##Coolant connector included with push-in type of connection - See Technical Documentation for detailed information
Product specific marine cert. +VBAB||American Bureau of Shipping##American Bureau of Shipping
Calculated Net Weight [kg] 460.000
Option slot F +CFXX||None, without mounting plate##No option - Field upgrade not possible
Product software ID +ECXXX||Latest released version##Latest official released version
DC Bus current 1436A(1025VDC)||1436A(1025VDC)
Additional drive features 4 +DG4X||None
Cooling type Liquid Cooled||Liquid Cooled
DC power 1471kW(1025VDC)||1471kW(1025VDC)
Frame designation 2XAR12L||2xAR12L
Recommended Plant ERR01||ERR01
Option slot H +CHXX||None, without mounting plate##No option - Field upgrade not possible
Option slot I +CIXX||None, without mounting plate##No option - Field upgrade not possible
Typecode Part 1 7SM-MASL3A07-1230E00F4
Option slot J +CJXX||None, without mounting plate##No option - Field upgrade not possible
Main unit Depth 566mm/22.3in||566mm/22.3in
Product View (Switch) GLBL||Global (Standard)
Modelcode09 +VBAB
Option slot D +CDXX||None, without mounting plate##No option - Field upgrade not possible
Modelcode04 +BGK1+BH15+BK03+BL25
Product category SL||System module, liquid-cooled
Current rating -1230||1230 A
ECCN US 3A999.a||3A999.a
Additional drive features 1 +DD1X||None
Option slot G +CGXX||None, without mounting plate##No option - Field upgrade not possible
Additional drive features 5 +DH5X||None
Control panel +BF20||Control Panel 2.8 OPX20##Control Panel with user interface, status and fieldbus indicators
Additional drive features 3 +DF3X||None
Product group IC7-60||iC7-60##Product is based on iC7-60 hardware series
Product series +DAMA||iC7-Marine
Additional drive features 2 +DE2X||None
Nominal AC current 1256A||1256A
Short circuit current rating 100kA||100kA
Mains voltage 07||525-690 V AC / 640-1100 V DC##Voltage range 525-690 V AC / 640-1100V DC
Documentation language +EHEN||English
Option slot A +CAXX||None, without mounting p##Option slot is not available
Option slot B +CBXX||None, without mounting plate##Option slot is not available
Modelcode03 +AO20+BAMT+BDC1+BEXX+BF20
Option slot E +CEXX||None, without mounting plate##No option - Field upgrade not possible
Option slot C +CCXX||None, without mounting plate##No option - Field upgrade not possible
Cross-Plant Configurable Material iC7-Marine System Module
DC fuses and devices +AKFX||DC bus fuses##Input protection with DC fuses
Marine construction +AFXX||None##Liquid cooled system modules allow two power cables per phase asstandard. Power terminal adapter allows three parallel but smallercross-section power cables.
check if complete OK||OK
Mains input device +AJFX||AC fuses##Input protection with AC fuses
Storage temperature -40...70°C/-40...158°F||-40...70°C/-40...158°F
Integration unit +AEZ1||Standard, with LC filter##Standard Integration unit with LC filter
Language package +EL01||Global##Global language package - See Technical Documentation for detailed information
Main unit Width 2x235mm/9.3in||2x235mm/9.3in
Functional safety +BEXX||None, not upgradable##No functional safety supported - not possible to upgrade later with FS related functionality
Communication interface, X1/X2 +BAMT||Modbus TCP OS7MT##Modbus TCP - PRP. Safe fieldbus not possible.
Salescode part 3 +AO20+BAMT+BDC1+BEXX+BF20||+AO20+BAMT+BDC1+BEXX+BF20
Customer-specific label +EJXX||None##No customer specific information printed on product label
Customization file package ID +EAXXXXXX||No customization##No customer specific settings
ECCN EU Y901||Y901
Apparent power /1306kVA(600VAC)||/1306kVA(600VAC)
Salescode part 7 +VBAB||+VBAB
High speed enabled +DI6X||No##Output frequency limited to 590 Hz
Apparent power 1502kVA(690VAC)||1502kVA(690VAC)
EMC category F4||C4 category##Suitable in systems with rated currents <gt/>= 400 A or IT supply systems for use in complex systems in the second environment. EMC plan required.
Extra environmental protection +AGCX||Coated boards##Coated printed circuit board for extra protection
Salescode part 6 +EGIN+EHEN||+EGIN+EHEN
Marine Certificate Number 141F8718||141F8718
Control panel cable length +BH15||1.5 m (5 ft)##Extension cable 1.5m (5ft)
AC voltage 3X525-690VAC||3X525-690VAC
Power factor cos φ = 1||cos φ = 1
DC Bus voltage 640-1100VDC||640-1100VDC
Salescode part 1 IC7-60SL3A07-1230E00F4||IC7-60SL3A07-1230E00F4
Control unit cable length +BK03||0.3 m (1 ft), Fiber##Optical fiber cable 0.3 m (1 ft)
Customer specific application +DBXX||None
Salescode part 4 +BGK1+BH15+BK03+BL25||+BGK1+BH15+BK03+BL25
📄
Cybersecurity iC7 System Products User guide • İndir
📄
iC7 Series System Modules Safety guide • İndir
📄
iC7 Series Liquid-cooled System Modules Design guide • İndir
📄
iC7 Series Functional Safety, Air-cooled and Liquid-cooled System Modules Operating guide • İndir
📄
iC7-Marine and iC7-Hybrid Selection Guide Brochure • İndir
📄
Functional Extension Options Operating guide • İndir
📄
Connecting to iC7 Series Remotely via Mobile Network Application guide • İndir
📄
iC7 Series Active Front End SW 5.4.2, FW 5.36.2 Application guide • İndir
📄
iC7 Series Liquid-cooled System Modules Installation guide • İndir
📄
iC7 Series Modbus Operating guide • İndir
📄
iC7-Marine and iC7-Hybrid Selection Guide - US English Brochure • İndir
📄
iC7 Open Source Software Declaration 23042026 Rev.01 Manufacturer's Declaration • İndir
📄
NKTA25002M Marine Certificate • İndir
📄
LR - MarineType Approval (LR2446207TA) Marine Certificate • İndir
📄
BV - Marine Type Approval (75215/A0 BV) Marine Certificate • İndir
📄
SGS FI-70924 CB Test Certificate • İndir
📄
ABS - Marine Type Approval (23-2453826-PDA) Marine Certificate • İndir
📄
KR - Marine Type Approval (HMB28683-AC004) Marine Certificate • İndir
📄
TÜV Z10 099224 0002 Functional Safety Certificate • İndir
📄
RINA - Marine Type Approval (ELE109523XP) Marine Certificate • İndir
📄
KR - KC EMC registration (KC - R-R-Ddk-IC7) EMC Certificate • İndir
📄
EU Data Act declaration for iC7 System products-Danfoss 00786811 Manufacturer's Declaration • İndir
📄
Danfoss EU 00773630 EU Declaration • İndir
📄
DNV TAE00004S2 Marine Certificate • İndir
📄
SGS FI-70913 CB Test Certificate • İndir
📄
TUV IT 26 CYB A 031 rev.00 Cyber Security • İndir
Danfoss 167G6096 kodlu ürün orijinal mi ve garantisi var mı? +

Evet, DES Teknoloji, Danfoss Türkiye partneridir. İncelediğiniz Danfoss iC7-Marine System module, liquid-cooled, 3~, regenerative, AFE, 525-690 V AC / 640-1100 V DC, 1230 A, Not relevant, IP00/Open Type, 2xAR12L ürünü %100 orijinal olup fabrika garantisi altındadır.

Danfoss 167G6096 sürücüsü için teknik servis ve tamir hizmeti veriyor musunuz? +

Evet. DES Teknoloji olarak uzman mühendis kadromuzla Danfoss sürücüleriniz için yetkili bakım, onarım, yedek parça ve test hizmeti sunmaktayız.

Bu ürünün kurulumu ve devreye alınması için destek veriyor musunuz? +

Satış sonrası mühendislik hizmetlerimiz kapsamında cihazın pano montajı, parametre ayarları ve sahada devreye alınması konularında teknik destek sağlamaktayız.

167G6096 sipariş kodlu ürün için nasıl fiyat teklifi alabilirim? +

Sayfadaki 'Proje İçin Teklif Alın' butonuna tıklayarak veya iletişim numaralarımızdan satış mühendislerimize ulaşarak özel iskontolu fiyat teklifinizi hemen alabilirsiniz.

× Tam Boyut