Danfoss iC7-Automation Frequency converter,air-cooled, 3~, 380-500 V AC, 1120 A, 630 kW/900 hp, IP54/UL Type 12, FB12

Sipariş / Malzeme Kodu: 167H3677 Kopyalandı ✓
Model Kodu (Typecode): 7FC-AUFA3N05-1120E54F3-000215286+BAPR+BDBA+BEF2+BF20+DAAU Kopyalandı ✓
Öne Çıkan Özellikler
  • • iC7-60 / Frequency converter,air-cooled
  • • 630 kW/900 hp
  • • 380-500 V AC
  • • IP54/UL Type 12
  • • Frame: FB12
  • • C3 category
  • • Control Panel 2.8 OPX20
  • • 4xDI, 2xDI/O, 2xAI, 1xAO, 2xRO
  • • None, not upgradable
  • • PROFINET RT OS7PR, Ethernet port, no protocol
  • • STO, SS1-t, fieldbus
  • • Latest released version
  • • Global
Teknik Parametre Değer
Input frequency 50/60Hz||50/60Hz
Product Catalog NO_VIEW||NO VIEW
Modelcode05 +DAAU
Enclosure rating IP54 / TYPE 12||IP54 / TYPE 12
Modelcode01 IC7-60FA3N05-1120E54F3
Modelcode02 +AGCX+AJFD
Main unit Height 2044 mm / 80.5 in||2044 mm / 80.5 in
Overload current IH (1/10min) 1500/1344A||1500/1344A
Input current in High Overload 963/863A||963/863A
Overload current IH (1/5min) 1340/1176A||1340/1176A
Overload current IL (1/10min) 1232/1131A||1232/1131A
Continous current IH (1/10min) 1000/896A||1000/896A
Continous current IH (1/5min) 880/784A||880/784A
Efficiency class-Relative loss IE2 - 1.82%||IE2 - 1.82%
Continous current IL (1/10min) 1120/1028A||1120/1028A
Main unit Depth 510 mm / 20.1 in||510 mm / 20.1 in
Touch protection +AMXX||None##No touch protection
Product specific marine cert. +VBXX||None##No approval
Modelcode04 +BEF2+BF20
ECCN US 3A999.a||3A999.a
Technical documentation +EGIN||Installation guide##Includes Installation Guide and Safety Guide
Power rating 630||630 kW/900 hp
Option slot D +CDX0||None##No option in option slot. Field upgrade possible
Product software ID +ECXXX||Latest released version##Latest official released version
Product series +DAAU||iC7-Automation
Modelcode03 +BAPR+BDBA
Standard I/O +BDBA||4xDI, 2xDI/O, 2xAI, 1xAO, 2xRO##Basic I/O (4 DI, 2 DI/DO, 2 AI, 1 AO, 2 NO/NC relays)
Protection rating E54||IP54/UL Type 12##IP54/UL Type 12 frames are designed for use in environments where the drive is exposed to both dust and water.
Cross-Plant Configurable Material iC7-Automation Frequency Converter
Mains voltage 05||380-500 V AC##Voltage range 380-500 V AC - Current rating given at 400V AC
Option slot A +CAX0||None##Option slot is empty, but available to add option later
Option slot B +CBXX||None, not upgradable##Option slot is not available
Product group IC7-60||iC7-60##Product is based on iC7-60 hardware series
Product category FA||Frequency converter,air-cooled
Option slot C +CCX0||None##No option in option slot. Field upgrade possible
Option Slot E +CEX0||None##No option in option slot. Field upgrade possible
Integrated common-mode filter +AIXX||None##No High Frequency common mode filter integrated
Current rating -1120||1120 A
Mains input device +AJFD||AC fuses and mains switch##Input mains switch and AC fuse input protection
ECCN EU Y901||Y901
Functional safety +BEF2||STO, SS1-t, fieldbus##STO (Safe Torque Off), SS1-t (Safe Stop 1, time controlled), configurable inputs and safe fieldbus support (refer to selection group "Communication interface, X1/X2) - can be upgraded later with more Functional Safety related functionality
Language package +EL01||Global##Global language package - See Technical Documentation for detailed information
Frame designation FB12||FB12
Extra environmental protection +AGCX||Coated boards##Coated printed circuit board for extra protection
EMC category F3||C3 category##Suitable for installation in the 2nd environment only, max. motor cable length up to 300 meters
Heat sink access panel +APXX||None##No heat sink access plate
Humidity protection device +AHXX||None##None
Interface board +BISR||MicroSD card reader and RTC##Interface board, MicroSD card reader and Real Time Clock (RTC) with battery backup
Integrated brake chopper +ACXX||None##No brake chopper
Control panel +BF20||Control Panel 2.8 OPX20##Control Panel with user interface, status and fieldbus indicators
Output frequency 0-590Hz||0-590Hz
Customer-specific label +EJXX||None##No customer specific information printed on product label
Calculated Gross Weight [kg] 363.550
Ambient temp LO (1/10 min) 40°C/104°F||40°C/104°F
DC terminals +ALXX||None##No DC terminals
Customization file package ID +EAXXXXXX||No customization##No customer specific settings
Vendor ERR01||Cannot Determine Vendor
Communication interface, X1/X2 +BAPR||PROFINET RT OS7PR##PROFINET RT - Application class 3. MRP, shared device, PROFIenergy, PROFINET diagnostics (ALARM CR) and extended diagnostics. To enable PROFISAFE use the configuration group "Functional Safety".
Ambient temp. high overload 45°C/113°F||45°C/113°F
High speed enabled +DI6X||No##Output frequency limited to 590 Hz
Input current HO (1/10 min) 963/863A||963/863A
Typecode Part 2 -000215286
Cable entry and EMC plate +AAST||Standard plate
Ambient temp. normal overload 40°C/104°F||40°C/104°F
Brand iC7
Customer specific application +DBXX||None
Calculated Net Weight [kg] 310.440
Communication interface, X0 +BBEL||Ethernet port, no protocol##Control card with Ethernet port X0, but no embedded protocol - can be upgraded later
Input current LO (1/10 min) 1078/990A||1078/990A
Additional drive features 5 +DH5X||None
Typical motor power PH (150%) 560KW(400V)/750HP(460V)||560KW(400V)/750HP(460V)
Recommended Plant ERR01||ERR01
Typecode Part 1 7FC-AUFA3N05-1120E54F3
Additional drive features 3 +DF3X||None
Maximum Power Loss LO [W] 13354||13354
Additional drive features 2 +DE2X||None
Typical motor power PH2 (150%) 500kW(400V)/650HP(460V)||500kW(400V)/650HP(460V)
Additional drive features 4 +DG4X||None
Typical motor power PL (110%) 630kW(400V)/900HP(460V)||630kW(400V)/900HP(460V)
Product type 3N||3~##Three phase supply - rectifier input
Short circuit current rating 100kA||100kA
Additional drive features 1 +DD1X||None
Input Voltage 3x380-500V||3x380-500V
Main unit Width 698 mm / 27.5 in||698 mm / 27.5 in
Control Board type A5E||Advanced Ethernet A5E##Advanced control board with Dual Ethernet interface and 24V external supply
Product View (Switch) GLBL||Global (Standard)
Ambient temp HO2 (1/5 min) 45°C/113°F||45°C/113°F
Input current in Normal Overlo 1078/990A||1078/990A
Ambient temp HO (1/10 min) 45°C/113°F||45°C/113°F
Input curent HO2 (1/5 min) 860/755A||860/755A
Danfoss 167H3677 kodlu ürün orijinal mi ve garantisi var mı? +

Evet, DES Teknoloji, Danfoss Türkiye partneridir. İncelediğiniz Danfoss iC7-Automation Frequency converter,air-cooled, 3~, 380-500 V AC, 1120 A, 630 kW/900 hp, IP54/UL Type 12, FB12 ürünü %100 orijinal olup fabrika garantisi altındadır.

Danfoss 167H3677 sürücüsü için teknik servis ve tamir hizmeti veriyor musunuz? +

Evet. DES Teknoloji olarak uzman mühendis kadromuzla Danfoss sürücüleriniz için yetkili bakım, onarım, yedek parça ve test hizmeti sunmaktayız.

Bu ürünün kurulumu ve devreye alınması için destek veriyor musunuz? +

Satış sonrası mühendislik hizmetlerimiz kapsamında cihazın pano montajı, parametre ayarları ve sahada devreye alınması konularında teknik destek sağlamaktayız.

167H3677 sipariş kodlu ürün için nasıl fiyat teklifi alabilirim? +

Sayfadaki 'Proje İçin Teklif Alın' butonuna tıklayarak veya iletişim numaralarımızdan satış mühendislerimize ulaşarak özel iskontolu fiyat teklifinizi hemen alabilirsiniz.